Model Number: APS 650 ~ 850VA
Brand Name: AWP
Key Specifications/Special Features:
Features:Microprocessor-based digital controlBoost and buck AVR for voltage stabilizationAuto sensing frequency
Wide input voltage range
Power-on self test
Cold start
Auto restart when mains power is restored
Auto track mains phase to ensure that inverter output voltage has same phase with utility voltage, reducing transfer time and peak surge
Intelligent battery management: battery temperature compensation to extend the battery life:three-stage charging to shorten recharge time
Short circuit, battery overcharge/overdischarge, overload, surge protections
Automatic charging in off mode
2 USB charger with 5V/1 A output (6 Schuko output model only)
Optional RS232 / USB communication port and RJ11 protection
Model | APS 650 | APS 850 | ||
Capacity | 650VA/360W | 850VA/480W | ||
Numbers of parallel module | 1-4 | 1-8 | ||
Numbers of redundancy module | 0-3 | 0-7 | ||
Rated capacity of each power module | 20kVA/20kW | |||
Input | ||||
Rated voltage | 380/400/415V AC | |||
Voltage range | 204-242 V AC (load ≤ 50%) 242-277V AC (50% < load ≤ 70%) 277-520V AC (70% < load ≤ 100%) |
|||
Rated frequency | 50/60Hz (auto-sense) | |||
Frequency range | 40-70Hz | |||
Power factor | ≥ 0.99 | |||
Bypass voltage range | ≤ 3% | |||
Delayed start of rectifier | rated output voltage: - 40%- + 20% (settable via LCD) | |||
Output | ||||
Voltage | 380/400/415V AC | |||
Voltage regulation | ± 1% | |||
Frequency | battery mode: 50/60Hz ± 0.1% mains mode: synchronized with utility frequency conversion mode: 50Hz input and 60Hz output or 60Hz input and 50Hz output |
|||
Waveform | Sinusoidal | |||
Power factor | 0.9 | |||
Crest factor | 3:1 | |||
Total harmonic distortion (THDV) | ≤ 2% (linear load) ≤ 5% (non-linear load) |
|||
Transfer time | AC mode to battery mode: 0 minute inverter mode to bypass mode: 0 minute inverter mode to eco-friendly mode: 5-10 minutes |
|||
Inverter overload capability | 105%: longtime running 105-110%: transfer to bypass in 1H 110-125%: transfer to bypass in 10 minutes 125-150%: transfer to bypass in 1 minute 150-200%: transfer to bypass in 200 minutes > 200%: transfer to bypass in 100 ms |
|||
Slight adjustment of inverter output voltage | ± 5V | |||
Batteries | ||||
DC voltage | ± 240V DC (± 192 / ± 204 / ± 216 / ± 228V DC selectable) | |||
Inbuilt battery of standard model | 12V/9Ah x 40 for each module | |||
Charging current | 1-30/60 A (settable via LCD) | |||
System | ||||
Efficiency | ≥94% | |||
Display panel | 5.7 inches LCD touchscreen | |||
Protections | short-circuit, overload, over-temperature, overvoltage, undervoltage, IGBT pulse -by pulsecurrent limiting, early warning of battery low voltage and battery overcharge protections | |||
Alarm | battery mode, low battery, fans fault | |||
EMI | EN62040-2 | |||
EMS | IEC61000-4-2 (ESD) IEC61000-4-3 (RS) IEC61000-4-4 (EFT) IEC61000-4-5 (Surge) |
|||
Communicaitons | ||||
RS232/RS485/USB/dry contacts (standard) | supports Windows 98/2000/2003/XP/Vista/2008/7/8/10 | |||
SNMP (option) | power management from SNMP manager and web browser | |||
Others | ||||
Humidity | 0-95% RH at 0 to 40°C (non-condensing) | |||
Noise level | ≤ 60dB | |||
Module dimensions | (W) 482 x (D) 590 x (H) 590mm | |||
Module weight | 28kg/power module, 27 kg / charger module, 7kg /monitoring module | |||
UPS dimensions | (W) 600 x (D) 1000 x (H) 1600mm | (W) 600 x (D) 1000 x (H) 2000mm | ||
UPS packing | (W) 700 x (D) 1070 x (H) 1070mm | (W) 700 x (D) 1070 x (H) 2060mm | ||
UPS weight Without inbuilt battery and power module |
Net weight: 225kg Gross weight: 245kg |
Net weight: 290kg Gross weight: 310kg |
||
Input /output/bypass breaker | yes | yes |
Shipping Information:
- FOB Port: Shenzhen
- Lead Time: 15 - 30 days
Main Export Markets:
- Asia
- Australasia
- Central/South America
- Eastern Europe
- Mid East/Africa
- North America
- Western Europe